Tp-Link S7500-26XF6Y

The TP-Link S7500-26XF6Y provides 6 x 25G SFP28 uplinks and 20 x 10G Ethernet ports, designed to deliver exceptional performance for high-speed networks. Featuring Layer 3 routing, Omada SDN integration, and stacking support, it is ideal for large-scale deployments requiring advanced traffic management, security, and centralized cloud-based management. Perfect for data centers, enterprise networks, and high-performance environments.

We are trying hard to provide best price, still not satisfied. Let us know


    Please prove you are human by selecting the house.

    • Pick up from the FGTECH Store

    To pick up today

    0-1 Days

    Free

    • Courier delivery

    Our courier will deliver to the specified address

    4-7 Days

    Free

    • Porter / WeFast

    Currently available only in Mumbai

    0-1 Days

    To be paid directly to service vendor

    • Fast Delivery ( By Air )

    We ship your products by air to the nearest delivery center to ensure faster and more reliable delivery.

    2-4 Days

    Start from Rs250 Extra

    SKU: FGIN5X82KQAJ Categories: , Brand:
    Description

    The TP-Link S7500-26XF6Y is a powerful 26-Port 10G Ethernet Switch designed for high-performance networking in enterprise environments. Tp-Link S7500-26XF6Y comes With a robust feature set, this switch is ideal for data centers, large offices, and businesses that demand high-speed connectivity and reliable performance.

    The TP-Link S7500-26XF6Y is an ideal solution for businesses seeking a high-capacity, reliable, and secure networking switch. Tp-Link S7500-26XF6Y comes With its advanced features, flexible connectivity options, and robust performance, this switch is designed to support the demanding requirements of modern network environments.

    • 26× 10 Gbps SFP+ slots and 6× 25 Gbps SFP28 slots
    • Physical stacking for built-in redundancy and performance
    • L3 Features: OSPF, BGP, IS-IS, VRRP, PIM-SM/PIM-DM/PIM-SSM, ECMP, PBR
    • Security Strategies: Secure Boot, RADSEC, IMPB, SFTP, 802.1X, Port Security
    • Highly available with two field-replaceable power supplies,* VRRP, ERPS, BFD
    • Easy O&M: NETCONF, Configuration Rollback, Hot Patching, and RSPAN
    • Centralized cloud management via the web or the Omada app

    About TP-Link

    Buy genuine TP-Link networking products in India, including Wi-Fi routers, switches, access points, and more. Explore TP-Link routers and other TP-Link products from FGTECH STORE, an authorised distributor.

    Product Details

    Brand NameTp-Link
    Model Name S7500-26XF6Y
    Dimension(cm)
    44.0 cm × 38.0 cm × 4.4 cm
    Weight(kg)4
    HARDWARE FEATURES
    Interface• 26× 1/10Gbps SFP+ Slots** • 6× 1/10/25Gbps SFP28 Slots • 2× USB 3.0 Ports • 1× RJ45 Console Port • 1× USB Type-C Console Port • 1× RJ45 Management Port
    Fan QuantityFour Field-replaceable and Hot-swappable Fans
    Power SupplyTwo Field-replaceable and Hot-swappable Power Supply Modules*(100–240 VAC, 50/60 Hz)*Shipping with one PSM550-AC module by default, and another field-replaceable redundant power supply requires purchasing separately.
    Dimensions ( W x D x H )17.3 × 15.0 × 1.7 in (440 × 380 × 44 mm)
    MountingRackmountable
    Max Power Consumption86.7 W (110 V/60 Hz)
    Max Heat Dissipation295.85 BTU/hr (110 V/60 Hz)
    PERFORMANCE
    Switching Capacity820 Gbps per Unit
    Stacking• Stacking Number: 12 (standalone mode) • Stacking Port: 25G SFP28 Slot (all uplink ports can be used as stacking ports)*** • Stack Bandwidth: Up to 300 Gbps (6 stacking ports)
    Packet Forwarding Rate610.1 Mpps
    MAC Address Table128 K
    Packet Buffer Memory8 MB
    Jumbo Frame9 KB
    SOFTWARE FEATURES
    Quality of Service• Class of Service - 8 Queues of Priority - Port Priority - IEEE 802.1p Priority - DSCP Priority - Queue Min-Bandwidth - Schedule Mode (SP, WRR, SP+WRR) • Bandwidth Control - Rate Limit - Storm Control • Voice VLAN • User-Defined OUI • Smoother Performance • Action for Flows - QoS remark (802.1P Remark, DSCP Remark) • WRED profile: 64
    L3 Features• L3 Interface: 256 (IPv4,IPv6) • Static Route: 2,048 IPv4, 1,024 IPv6 • Host Route Table: Max 15,300 entries • IPv4 Network Router entries: 102,400 (shared with IPv6 Network Router entries) • IPv6 Network Router entries: 51,200 (shared with IPv4 Network Router entries) • ECMP: 256 entries, max 32 ECMP Nexthops per Destination • Static ARP: 1,024 static entries • Dynamic ARP: 24,576 dynamic entries • ND: 24576 • DHCP Server: Max 64 IP pool, Max 8,000 IP entries • DHCPv4/v6 Relay • VRRP: Version v2/v3, Max 64 instances, Max 32 Virtual IP per instance • OSPFv2 - OSPF Instance: 16 - Network Entries: 256 entries - Area Entries for Stub or NSSA: 16 per instance - Area Range Entries: 16 per instance - Virtual-link Entries: 16 per instance • OSPFv3 - Area Entries for Stub or NSSA: 16 per instance - Area Range Entries: 16 per instance • RIPv1/v2 - Network Entries: 256 - Redistribute Entries: 20 • RIPng • IS-IS - IS-IS Interfaces: 128 - IS-IS Area Numbers: 3 - Max Redistribute Configs: 10 - IS-IS IPV6 - IS-IS BFD • BGP: Max 20 redistribute configs • PIM-SM/PIM-DM/PIM-SSM - IP Multicast Route Entries: 1K - PIM Neighbors: 256 - Max PIM Interfaces: 128 • IGMP: Version v1/v2/v3, Max 2,048 multicast groups • BFD: 16 template numbers, 8 session numbers • PBR • uRPF
    L2 and L2+ Features• Link Aggregation • Spanning Tree Protocol • Port-based and VLAN-based Loopback Detection • 802.3x Flow Control • ERPS • Mirroring • RSPAN • MAC Address Table • Multicast - IGMP Snooping - MLD Snooping - Multicast VLAN Registration (MVR) - Max Multicast Table: 4K (IPv4, IPv6) - Fast Leave - Static Multicast Groups - Multicast Filtering - IGMP Snooping Authentication
    Advanced Features• Automatic Device Discovery • Batch Configuration • Batch Firmware Upgrading • Intelligent Network Monitoring • Abnormal Event Warnings • Unified Configuration • Reboot ScheduleISP Features: • 802.3ah Ethernet Link OAM • L2PT (Layer 2 Protocol Tunneling) • Device Link Detect Protocol (DLDP) • DDM • sFlow
    VLAN• Max 4K VLAN Group (802.1q VLAN) • 802.1Q Tagged VLAN • MAC VLAN Entries: 200 • Multicast VLAN • Management VLAN • VLAN VPN (QinQ): Max 256 entries • GVRP • Protocol VLAN: Protocol Template 16, Protocol VLAN 12 entries • Voice VLAN • Private VLAN
    Security• Port Isolation • CPU-Defend • ARP Inspection (Dynamic ARP Inspection) • DoS Defend • IP-MAC-Port Binding -1,024 Entries - DHCP Snooping - ARP Inspection - IPv4 Source Guard • IPv6-MAC-Port Binding -1,024 Entries - DHCPv6 Snooping - ND Detection - ND Snooping - IPv6 Source Guard • DHCP Filter • Static/Dynamic Port Security - Up to 64 MAC addresses per port • Broadcast/Multicast/Unknown-unicast Storm Control - kbps/ratio control mode • 802.1X - Port base authentication - Mac base authentication - VLAN Assignment - MAB - Guest VLAN - RADIUS authentication and accountability support • AAA (including TACACS+) • Secure web management through HTTPS with SSLv3/TLS 1.2 • Secure Command Line Interface (CLI) management with SSHv2 • IP/Port/MAC-based access control • Secure boot • RADSEC
    MANAGEMENT
    Omada AppYes, through Omada Pro Controller
    Centralized Management• Omada Pro Cloud-Based Controller • Omada Pro Hardware Controller • Omada Pro Software Controller
    Cloud AccessYes, through Omada Pro Controller
    Zero-Touch ProvisioningYes. Requiring the use of Omada Pro Cloud-Based Controller.
    Management Features• Web-based GUI • Command Line Interface (CLI) through console port, telnet • SNMPv1/v2c/v3 - Trap/Inform - RMON (1, 2, 3, 9 groups) • SDM Template • DHCP/BOOTP Client • 802.1ab LLDP/LLDP-MED • DHCP Auto Install • Dual Image, Dual Configuration • CPU Monitoring • Cable Diagnostics • Password Recovery • SNTP • System Log
    OTHERS
    Package Contents• S7500-26XF6Y Switch • Power Cord • RJ45 Console Cable • Quick Installation Guide • Rackmount Kit • Rubber Feet
    System RequirementsMicrosoft® Windows® 98SE, NT, 2000, XP, Vista™ or Windows 7/8/10/11, MAC® OS, NetWare®, UNIX® or Linux.
    Environment• Operating Temperature: -5 °C to 50 °C (23 °F to 122 °F) @ 300 meters -5 °C to 45 °C (23 °F to 113 °F) @ 2,000 meters -5 °C to 40 °C (23 °F to 104 °F) @ 3,000 meters• Storage Temperature: -40 °C to 70 ℃ (-40 ℉ to 158 ℉) • Operating Humidity: 10–90% RH non-condensing • Storage Humidity: 5–90% RH non-condensing
     

    Datasheet
    Reviews & Q and A

    Reviews

    There are no reviews yet

    Only logged in customers who have purchased this product may leave a review.

    Q & A

    Ask a question
    You must be logged in to ask a question Log In
    There are no questions yet

    RELATED PRODUCTS